My title

760.738.4084

Mercedes-Benz ABC Filter Kit

Mercedes-Benz ABC Filter Kit
X

Part Number: AGA-MB-ABC-FK
Price: $46.00
$46.00
  • When you perform a flush on a Mercedes-Benz ABC system it is very important to replace the filter in the system to remove any contaminants that have built up.
  • For ease and convince we offer a Mercedes-Benz factory ABC filter kit.
  • Note: This filter is for newer ABC systems where the fluid is returned to the reservoir through the bottom of the reservoir, NOT for the style where the fluid is returned through the top of the fluid cap.
Downloadable PDFs

Models This Product Fits

  • This product fits Mercedes-Benz vehicles with Active Body Control (ABC). The fluid is returned through the bottom of the ABC reservoir, not through the top of the reservoir cap.

Parts Included

Quantity 1
Part # AGA-MB-ABC-FT
Description Replacement Filter
Total $46.00

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Quality
Ease-of-Use

STEP 1

Verify that fluid level is in ABC reservoir is full, correct fluid level if needed.

STEP 2

Warm up ABC system to 80°C or 176ºF by Connect Star Diagnosis system and under Suspension menu select “Activate all suspension struts alternately in circular sequence (rodeo)” and start activation. Process will take approximately 15 min.

STEP 3

After warming up system shut off engine and removed large fill cap from reservoir which has the ABC system filter attached to the bottom of it.

STEP 4

Insert the AGA Mercedes-Benz ABC Flushing Tool through the large opening in the top of the reservoir and press it down firmly so that it seals into the return port in the bottom of the fluid reservoir. At the same time place the weighted end of the flush tool line into a suitable drain bucket (min. size 15L). Start engine and let it run at idle. In the Star Diagnosis System select “Actuations/Actuate front and rear suspension struts alternately (pitching)”. As the suspension is raised and lowered the old fluid will be pumped out though the tool and into the drain bucket. Monitor the ABC reservoir fluid level during this process, keeping it full to avoid sucking air into the system; do this by pouring fluid around the flush tool into the reservoir. Let system run and flush until approximately 10L of fresh fluid has been run through the system.

STEP 5

When flush is complete:

  • Stop “pitching” activation
  • Turn off engine
  • Remove flush tool from reservoir
  • Install new ABC Filter on reservoir cap
  • Reinstall reservoir cap
  • Set vehicle ride height in Star Diagnostic System
  • Correct fluid level in reservoir
  • Disconnect Star Diagnosis System